Fly braces are small but critical structural elements used in steel sheds, warehouses and industrial buildings to prevent lateral torsional buckling in beams and columns. By providing restraint to an otherwise unrestrained compression flange, a fly brace can significantly increase a member’s bending capacity and improve overall structural efficiency. This article explains how fly braces work, their role in resisting wind uplift conditions, and why they are often a more economical solution than increasing the size of primary steel members.

Quentin Suckling · November 2021 · 3 min read

What Is a Fly Brace and What Does a Fly Brace Do

In steel construction of sheds and warehouse buildings, there is a small element which has a huge impact on the overall performance of the building and its members. The aptly named fly brace can drastically improve a beam or columns performance due to its restraining characteristics. So, what is a fly brace, and what does a fly brace do? This article answers both…

A fly brace in construction terms is a short diagonal member, either a strap or angle section, connecting to an otherwise unrestrained flange of a spanning beam or column. The structural purpose of a fly brace is to restrain the member it attaches to against the phenomenon of lateral torsional buckling. This form of buckling is a twist or torsional response a member undergoes due to bending.

Cross-section view of an example fly brace arrangement. The fly brace attaches to an otherwise un-restrained flange of a spanning member to add restraint against lateral torsional buckling.
Cross-section view of an example fly brace arrangement. The fly brace attaches to an otherwise un-restrained flange of a spanning member to add restraint against lateral torsional buckling.

To understand exactly how a fly brace works, we need to understand the phenomenon of lateral torsional buckling…

The Fly Brace and Lateral Torsional Buckling

I strongly recommend that you first read THIS article which covers everything you need to know about lateral torsional buckling, what causes it, and how to prevent it so that you can fully grasp what a fly braces purpose is.

By way of quick explanation, lateral torsional buckling occurs in members which undergo bending. Beams develop internal coupling compression/tension forces as they bend. In the case of a steel rafter in a warehouse, under self-weight conditions, the top flange is in compression and the bottom flange in tension. Without restraint, the compression flange (top flange) tends to buckle horizontally which causes this form of torsional buckling…

Example Warehouse Application

Let's dig a little deeper at this example “i” section rafter mentioned above. In the self-weight and dead/live load condition, the top flange is in compression and is effectively restrained by the purlins that is supports…

Example arrangement of a rafter beam with downward loading and its top compression flange being restrained by the steel purlin that it supports
Example arrangement of a rafter beam with downward loading and its top compression flange being restrained by the steel purlin that it supports

In lightweight steel construction such as large warehouses and sheds however, the wind loading on the roof can generate a net up-lift and therefore an upward force on the steel rafter. This can result in a reversal of the internal forces. In this situation the bottom flange can undergo compression and the top flange tension. This can result in a very long unrestrained length for the bottom flange which can result in failure via lateral torsional buckling. The introduction of the fly brace provides this necessary restraint to prevent this buckling from occurring…

Elevation showing indicative wind behaviour when passing over a warehouse steel structure. The resultant influence on the structure is a series of upward, downward and horizontal win loads acting on individual members which make up the warehouse. This arrangement can change depending on the wind direction and geometry of the warehouse. The upward wind pressure requires that a fly brace be introduced to restrain the bottom flanges of the refers against buckling.
Elevation showing indicative wind behaviour when passing over a warehouse steel structure. The resultant influence on the structure is a series of upward, downward and horizontal win loads acting on individual members which make up the warehouse. This arrangement can change depending on the wind direction and geometry of the warehouse. The upward wind pressure requires that a fly brace be introduced to restrain the bottom flanges of the refers against buckling.
Cross section of a typical “i” section rafter loaded in a net upwards condition, generating compression in the bottom flange requiring a fly brace to be introduced to restrain against lateral torsional buckling.
Cross section of a typical “i” section rafter loaded in a net upwards condition, generating compression in the bottom flange requiring a fly brace to be introduced to restrain against lateral torsional buckling.

Without the fly braces restraining the bottom flange the rafter may need to be significantly increased in size to prevent it from buckling. It is generally a cheaper option to provide the fly braces in lieu of increasing the rafter size. The graph below shows the bending capacity of a 610UB101 (an “i” beam 610 mm deep or 24 inches), for varying unrestrained lengths. This shows how effective fly braces can be in adding strength to spanning members…

Graph of bending capacity for a 610UB101 “i” section against varying unrestrained lengths. This shows how effective fly braces can be in enhancing a beams strength capacity.
Graph of bending capacity for a 610UB101 “i” section against varying unrestrained lengths. This shows how effective fly braces can be in enhancing a beams strength capacity.

Never miss a new insight.

Receive email notifications when new articles, project lessons and technical insights are published.

Leave a message.

A thought, a question or a correction on this article — it comes straight to our team. Messages are reviewed by us before they appear beneath the article.

Looking For Advice?

Tell us about your building.

Can’t find the answer you’re looking for? Tell us about your building, project or challenge and we’ll help point you in the right direction.

About The Author

Quentin Suckling

Quentin Suckling

Director - Structural Engineering

Quentin Suckling is the Director and Principal Structural Engineer at Sheer Force Engineering. Passionate about heritage preservation and adaptive reuse, he enjoys understanding how buildings behave and helping clients unlock the potential within existing structures. Through these articles he shares practical lessons from projects, investigations and engineering practice.